Arizona has the best solar resource in the country and some of the dirtiest panels. Months without rain, agricultural dust in the East Valley, construction dust everywhere, monsoon haboobs and hard-water spotting from the little rain that does fall all build a film on the glass that the sun cannot get through. Field studies in the desert Southwest put soiling losses at roughly 5–15% of output between cleanings, and a single dust storm can push a dirty array well past that. On a commercial array that is a line on your utility bill every month — and a maintenance item most janitorial vendors cannot touch. Covenant Facility Services cleans commercial solar arrays as part of the same exterior program that covers your power washing, under the same insurance certificate and schedule as your interior cleaning.
What we clean
- Rooftop commercial arrays on offices, warehouses, retail centers, schools and churches, with OSHA-compliant fall protection and roof-access coordination.
- Solar carports and canopies over parking lots at schools, medical buildings, offices and municipal sites — the most visible arrays in Arizona and the ones that collect the most parking-lot dust.
- Ground-mount arrays at industrial, agricultural and institutional facilities.
- Mixed portfolios — property managers with arrays on several buildings get one schedule, one invoice and one report.
How we clean solar panels
Panel manufacturers' care guidance is specific, and we follow it:
- Purified water only. Deionized or reverse-osmosis water lifts dust and dries spot-free. Tap water leaves the mineral haze that makes Arizona panels look clean and perform dirty.
- Soft brushes, never high pressure. Rotating soft-bristle brushes on water-fed poles remove film and bird droppings without stressing the glass, the anti-reflective coating or the frame seals. Pressure washers void warranties and we do not use them on panels.
- No detergents unless the manufacturer approves one for a specific contaminant.
- Cool-panel scheduling. We clean early in the morning or on overcast days so cold water never hits hot glass, which protects the panels and reduces water spotting.
- Visual inspection while we work — cracked or discolored glass, loose connectors, damaged wiring, nesting under the array and drainage problems are photographed and flagged in your report so your solar contractor can act on them.
- Safety and site rules. Fall protection on rooftops, electrical-awareness training (we never open combiner boxes or disconnects), traffic control under carports, and coordination with your facilities team or O&M provider on access and any required shutdowns.
How often commercial panels need cleaning in Arizona
Most commercial arrays in the Phoenix and Tucson metros perform best on a quarterly to semi-annual schedule, with an extra cleaning after a major dust storm. Arrays next to farmland, construction, freeways or unpaved lots — and low-tilt carport arrays, which shed dust poorly — sit at the quarterly end. We will recommend a frequency after seeing the array and, where you can share inverter production data, help you confirm the output gain after the first cleaning.
What solar panel cleaning costs
Commercial solar cleaning is quoted per panel or per array, with the price driven by panel count, access (ground, carport or roof), tilt, how dirty the array is and whether we are already on site for your janitorial or power-washing program. Large arrays earn volume pricing; a minimum visit fee applies to small ones. Book a walkthrough and we will send a written per-visit and annual price alongside your other exterior services. Read more about our exterior programs in our commercial power washing guide.
Where we clean solar panels
Phoenix East Valley — Queen Creek and San Tan Valley, Gilbert, Chandler, Mesa, Tempe, Scottsdale and Phoenix — plus the Tucson metro.
Frequently asked questions
Will cleaning void my panel warranty?
Not when it is done to the manufacturer's care guidance, which is what we follow: purified water, soft brushes, no high pressure, no unapproved chemicals, no cleaning of hot panels. Pressure washing and abrasive tools are what void warranties.
Do we have to shut the system down?
Usually not — water-fed soft-brush cleaning is routinely done on live arrays. We never open electrical enclosures, and if your O&M provider or site policy requires a shutdown we coordinate it in advance.
Can you tell me how much output I am losing to dirt?
If you can share before-and-after production data from your inverter or monitoring portal, we will help you compare it. Field studies in the desert Southwest typically find 5–15% soiling losses between cleanings, and the difference on a cleaned array is usually visible the same day.
Can you bundle solar cleaning with our janitorial contract?
Yes. Solar cleaning, power washing and your interior program can run under one contract, one certificate of insurance and one Facility Health dashboard, and bundling usually lowers the per-visit price.